Generated concept of control-cabinet wiring with terminal rows and a door connection loom

Generated control-cabinet wiring concept.

Control Panel Harness Constructions

Compare branched housing harnesses and mixed-end lead assemblies. Product illustrations are based on JTY samples.

Match the Wire End to the Terminal

The equipment connection determines the required end preparation. Record End A and End B separately, including the parts used at each end. The sample end structures do not establish a match to the Phoenix Contact reference below.

Compare the End Structures

Conductors entering a white connector housing on a JTY sample

Housing end

Conductors entering connector housings

Housing and contact part numbers, mating reference and cavity assignment

Ferrules with red insulating collars and identification sleeves on a JTY assembly

Ferrule

Metal tubes with red insulating collars

Target equipment terminal, conductor size and ferrule part number

Fork-type metal terminals on red and black leads in a JTY sample

Fork terminal

Open-ended metal terminals on individual leads

Terminal part number, equipment fastener size and connection orientation

JTY sample details.

Equipment-Terminal Reference

Phoenix Contact PT 2,5

Part number 3209510

Phoenix Contact PT 2,5 manufacturer product image showing the terminal constructionPhoenix Contact PT 2,5 connection data
Published connection data for this terminal
Flexible conductor0.14–4 mm²
Flexible conductor with ferrule, without plastic sleeve0.14–2.5 mm²
Flexible conductor with ferrule, with plastic sleeve0.14–2.5 mm²
Stripping length8–10 mm

Phoenix Contact lists the general connection range and directly pluggable range separately. Selecting a conductor within the general range does not establish that it meets the directly pluggable condition.

Directly Pluggable Connections

Ferrule without plastic sleeve0.5–2.5 mm²
Ferrule with plastic sleeve0.34–2.5 mm²

For this terminal, 0.25 mm² falls within the listed range for flexible conductors with plastic-sleeved ferrules. It falls below the 0.34 mm² minimum listed for direct insertion under that condition. These published values apply only to this terminal, not to JTY harness ratings.

Keep Stripping and Ferrule Dimensions Separate

Wire-end preparation illustration.
Illustration of a stripped conductor, a loose ferrule and a crimped ferrule

The terminal's stripping requirement and the ferrule's barrel length are separate entries. The termination specification records both. Housing ends also need the contact's conductor range and preparation requirements.

End A and End B each need an equipment or mating reference, end-part numbers, wire specification and termination requirements.

Discuss End Requirements

Turn Connection Points into a Wire List

Each wire-list row links a source terminal to a target terminal and records the wire and finished end treatments. Use the same wire ID on the BOM, markers and inspection record.

ABK Instal marking example: P14:X1 and P14:X2.ABK Instal panel assembly
ABK Instal control contact with yellow wire markers P14:X1 and P14:X2
X1:1
W101
K1:A1

Example connection W101 runs from terminal 1 on X1 to terminal A1 on K1. The identifiers are illustrative and are separate from the ABK photograph.

End treatment and marker text belong to the same connection record as the source and target. This lets the BOM, wire list and drawing refer to the same conductor during quotation and inspection.

Kit ID
CP-01
Drawing revision
B

Put Manufacturing Data on the Same Wire Record

Field groupInformation carried with each connection
WireWire specification, cross-section and colour
LengthCut length, measurement datums and tolerance
End A / End BTermination type, end-part numbers and cavity or terminal designation
MarkingText at each end, reading direction and position relative to the termination
Order referenceAssembly part number, drawing revision, kit ID and quantity

Dimension the Installation Route

The schematic defines the electrical connections. The route drawing defines the physical layout used to specify wire lengths and branches. The illustrations do not specify a bend radius or flex life; movement requirements belong in the project specification.

Fixed-cabinet routing illustration.
Fixed-cabinet routing illustration with wiring ducts, a branch and terminal rows

Fixed Cabinet Route

Wires routed through cabinet ducts need a defined path between their terminations. Branch locations and tail lengths describe where the assembly leaves that path.

Drawing entryMeasurement detail
End datumsNamed reference point at each termination
Route lengthLength along the specified path between the datums
Branch positionDistance from a stated datum to the breakout
Tail lengthDistance from the breakout to the stated end datum
TolerancePermitted variation for each controlled dimension
L1B1
Routing illustration. L1 identifies a reference span. B1 identifies a branch drop. Wire cut length follows the specified route and end datums.

Overall, branch and tail dimensions need their own datums and tolerances. Movement requirements belong with the cabinet-door route.

Specify the Kit and Ordered Quantity

Define the order unit before comparing quotations. Individual leads, assembled harnesses and cabinet kits carry different quantities and supply boundaries. Grouping and packaging are part of the agreed supply scope.

Proposed order unitWhat the order line defines
Individual leadOne wire reference and its finished end treatments
Harness assemblyOne assembly part number covering the specified branches and ends
Cabinet or functional kitOne kit ID listing the required assemblies, leads and loose items

Separate Kit Content from Order Quantity

Illustrative order calculation

Kit ID
CP-01
Drawing revision
B
Leads per kit
12
Ordered kits
10

12 leads per kit × 10 kits = 120 assembly leads

2 additional leads for W101

120 assembly leads + 2 spare leads = 122 leads

Keep Loose Items and Customer-Supplied Parts Visible

The BOM records the quantity per kit for each assembly and loose item. Spare leads remain separate order lines. Customer-supplied housings or contacts need their own part references and quantities.

Record the kit-list revision and the applicable assembly-drawing revisions on the order. Record branch or end-part changes in the kit content even when the ordered kit quantity stays the same.

Komax prepared-wire reference.
Komax reference photograph of prepared leads with ferrules and identification sleeves held together by a carrier strip

Agree the Acceptance Records

Inspection records need the same assembly or kit ID as the order. The drawing revision identifies the requirements used for acceptance. Test methods, limits and record coverage are defined by the agreed project scope; the tests listed below are not automatic requirements for every harness.

Inspection itemAcceptance basisRecord content
ConnectionsApproved source-to-target map and defined isolated circuitsConnection pairs covered by open- and short-circuit checks
IdentificationApproved wire IDs, end markings and cavity assignmentsMarking and cavity checks against the wire list
DimensionsDrawing datums and tolerances for overall, branch and tail lengthsMeasured values for the controlled dimensions
TerminationsRequirements for the selected contacts, ferrules and housingsApplicable crimp, contact-seating and housing-lock checks

Dimensions

Dimensional-check illustration.
Dimensional-check illustration with a branched harness and measurement stops

Terminations

Crimp cross-section illustration. Acceptance limits apply to the specified terminal and wire combination.
Illustration of a polished crimp cross-section specimen with copper strands

Separate Continuity from Other Test Requirements

Continuity checks use the defined connection map. Dielectric withstand, insulation resistance and pull-force tests need separate acceptance conditions.

Additional requirementInformation needed in the inspection scope
Dielectric withstandTest points, voltage, duration and pass criterion
Insulation resistanceTest points, test voltage and minimum resistance
Pull forceTerminal and wire combination, test method, sampling and acceptance force

Carry the Order Reference into the Record

Illustrative record header
Kit IDCP-01
Drawing revisionB
Record fieldsInspection date / inspected quantity / applicable requirements / results / disposition

Before the Drawing Is Released

What does a schematic or sample leave undefined?

A schematic shows electrical connections but may not specify the physical route, finished dimensions or end-part references. A sample can show the existing construction, but the connections and dimensions to retain still need to be identified. Any intended changes need to be reflected in the manufacturing drawing.

How should a housing or contact substitution be approved?

Compare the exact mating references, cavity arrangement and contact wire range. Include the termination requirements in the comparison. Matching pitch alone does not establish interchangeability. Record an approved replacement in the BOM. Update the drawing revision wherever the replacement changes its requirements.

Contact Us

Tell JTY about your connector, wire harness or cable assembly project. Share the drawings, specifications or sample details you have for an initial review.

    No file selected

    PDF, XLSX, CSV, JPG or PNG · up to 5 MB. Need an NDA? Mention it above.

    Samples in 3–7 days. Batch production about 30 days after order confirmation.