Industrial Automation
Wire Harnesses
JTY manufactures industrial automation wire harnesses and cable assemblies for machine tools, packaging machines, conveyors and inspection equipment. JTY molds custom cable ends in its own molding workshop. Samples are ready in 3–7 days once the configuration is agreed. Harnesses with no drawing can be copied from a sample.
JTY builds RJ45 Ethernet cables with a panel-mount jack that screws into the cabinet wall or door. A laptop plugs into the jack without opening the cabinet.
The inner end carries an RJ45 plug for the switch or PLC port inside the cabinet.
Industrial Harness Categories

M8/M12 Sensor Cable Assemblies
M8 and M12 cables connect sensors and actuators to I/O modules.
Single-ended leads · Double-ended cordsets · M8-to-M12 cordsets
View M8/M12 Sensor Cables
Control Panel Wiring Harnesses
Control panel harnesses connect terminals, control devices and panel connectors inside a cabinet.
Multi-branch harnesses with connector housings · Ferrule and terminal leads
View Control Panel Harnesses
Servo & Encoder Cable Assemblies
Servo power, brake and feedback cables run between drives and motors.
Motor power cables · Encoder feedback cables
View Servo & Encoder Cables
Industrial Ethernet & Fieldbus Cable Assemblies
Industrial Ethernet and fieldbus cables link PLCs, industrial PCs, switches and field devices.
RJ45 patch leads · M12 D-coded and X-coded cables
View Ethernet & Fieldbus Cables
Machine Vision Cable Assemblies
Machine vision cables carry data and power between inspection cameras and their host computers.
USB-C cables with locking screws · USB-A to Micro-B cables
View Machine Vision CablesHarnesses by Industrial Equipment

Machine Tools & CNC Equipment
Coolant and cutting oil reach the cables inside the machine enclosure. Oil-resistant PUR jackets protect these cables.

Packaging Machinery
Hardwired machines are wired and tested in the builder’s plant. They are disconnected for shipping and rewired on site. Plug-in cordsets let the machine sections reconnect on site without rewiring.

Food & Beverage Equipment
JTY’s IP67 waterproof harnesses with molded ends are rated for temporary immersion. High-pressure, high-temperature washdown zones call for IP69K-rated connectors.

Material Handling & Intralogistics
Conveyor zones spread sensors along the line. The distance from each sensor to its I/O module changes from zone to zone. JTY builds each cordset to the length on the drawing.

Electronics & Semiconductor Equipment
Inspection cameras on electronics and semiconductor equipment often use USB cables with locking screws. The screws hold the plug in the camera port under vibration and movement.

Textile Machinery
Knitting machines run at high stroke rates. Jacket abrasion and core durability decide which cable lasts on these machines. Cables on textile machines should have flame-retardant jackets.

Printing Equipment
Each printing unit on a sheet-fed press can have its own control box. One six-unit press uses about 2.7 km of cable. JTY can build the same control-box harness set for each unit from one drawing.

Test & Measurement Equipment
Test fixture connectors mate and unmate with every device tested. Connectors with thicker gold plating are generally rated for 500 mating cycles. Tin-plated connectors may be rated for as few as 10 to 50.
Mechanical and Environmental Tests · Control Panel Harnesses
From Drawing to Batch Production

Drawing or Sample Review
The JTY engineers who review your drawing or sample harness stay on the project through samples, batch production and repeat orders.
Sample in 3–7 Days
Sample and courier fees are quoted with the sample.
Sample Approval
You check fit, routing and connections on the sample. Batch production starts after you approve it.
Batch Production
Batch production takes about 30 days after order confirmation. The minimum batch order is 50 pieces.
Choosing the Harness Build
Single-Ended, Double-Ended or Branched

Fixed and Moving Sections
A widely used rule of thumb puts the minimum bend radius at 6–8 × the cable diameter for fixed installation. The same rule puts it at 10–12 × for drag chains and robots. Each cable’s datasheet gives its own rating. The cable’s bend radius sets the smallest drag chain radius it can run in. JTY’s wire bending tester checks how a cable holds up under repeated bends.

Shielding and M12 Coding
Shielding keeps servo drive noise off encoder and sensor signals. JTY builds shielded cables and shielded harnesses. M12 coding keys each connector to its use. A-coding carries sensor signals and DC power. B-coding carries PROFIBUS. D-coding carries 100 Mbit/s Ethernet over 4 pins. X-coding carries up to 10 Gbit/s Ethernet over 8 pins. A connector with a different coding does not mate with the device port.
Built in JTY’s Plant

Terminal Processing
JTY’s plant crimps terminals on automatic terminal machines. First samples come with a crimp cross-section report. The report shows the conductor compression for each terminal type on the sample.

Harness Assembly
JTY builds each harness in the wire colors on the drawing. Printed sleeves label each lead with its circuit. Matching circuit names on the drawing and the sleeve let an electrician trace a lead in the cabinet.

Injection Molding
A molded end supports the cable where it leaves the connector. A new mold carries a separate mold charge. A stock connector housing needs no new mold.
Tests on Industrial Harnesses
A temperature-rise check shows whether a power lead runs too hot at its working current. JTY can load a sample at your current and measure its temperature rise before the wire size is fixed.

Dimensions
JTY’s 2D optical measuring instrument measures terminal, crimp and molded-end dimensions.

Electrical Checks
JTY can check continuity, polarity and pin assignment on finished harnesses. JTY measures circuit resistance with a precision tester. JTY’s withstand-voltage tester checks insulation between circuits.

Mechanical and Environmental Tests
JTY measures mating force over repeated insertion and withdrawal cycles. JTY’s salt spray chamber checks terminals and connector shells for corrosion. Temperature-humidity testing checks insulation and contacts after damp heat. High and low temperature aging checks them after hot and cold exposure.
ISO 9001

IATF 16949

ISO 14001

UL

TÜV
Industrial Harness FAQ
Can two cables with matching connectors be used interchangeably?
Not necessarily. Even when the connectors mate, the contacts may be wired differently. Check the equipment's pin assignment and the cable's end-to-end wiring against the replacement before connecting it.
When is a right-angle connector useful instead of a straight one?
A right-angle connector can help where a straight cable exit has too little clearance. Check the direction of the exit and the space needed to attach and release the coupling; the best orientation depends on the device and its surroundings.
Can JTY use connectors we supply?
Yes. JTY assembles connectors supplied by the customer. JTY also sources the wire and connectors listed on the drawing.
Can we use a longer USB cable for a machine-vision camera?
Possibly, but a longer connection can affect both data transmission and the power available to the camera. Check the camera and host requirements together with the selected cable or extension; some active or optical solutions may need a separate power supply. Verify the complete connection with the equipment before use.
Should a cable shield be connected at one end or both ends?
The choice depends on the interference and grounding arrangement. Connecting both ends can improve protection against some interference, but differences in ground potential can also create unwanted current. Follow the equipment and system grounding design rather than applying one rule to every installation.
Contact Us
Tell JTY about your connector, wire harness or cable assembly project. Share the drawings, specifications or sample details you have for an initial review.
Your Project